FAQ'S
Compressor Valve Questions & Answers
- Seat
- Guard (guard, stop plate, buffer, plate, etc.)
- Sealing element (valve plate or valve ring, channel, poppet, feather strip, ball, etc.)
- Damping element (coil springs, cushion plates, spring plates, damping plates, etc.)
- Assembly element (bolts, nuts, retainer ring, etc.)
There are several different kinds of compressor valves: plate valves, ring valves, channel valves, feather valves, poppet valves, ball valves, reed and concentric valves. Each design has specific criteria with regard to the sealing element and all the other components are designed accordingly.
Not really, each valve is designed for a certain application and is best used in the range of operating conditions for which it was designed.
A compressor valve regulates the flow of air or gas in a compressor cylinder. There is at least one suction valve and one discharge valve for every compression chamber. Each valve opens and closes with every cycle of the piston. For example, a valve used in a compressor operating at 1200 r.p.m. for 24 hours a day and 365 days a year, opens and closes:
- 72,000 times per hour, or
- 1,728,00 times per day, or
- 630,720,000 times per year!
Compressor operators typically expect the valve to be:
- efficient
- durable
- quiet
Efficiency demands include aerodynamic flow efficiency and the volumetric efficiency. A durable valve should provide maintenance free operation over several thousand hours plus relative ease in servicing and repair.
The equivalent area is the orifice area in square inches of a valve which also has a given pressure loss. The potential performance differences of two valves can be established by comparing their equivalent areas.
The higher the equivalent area, the better the flow efficiency.
Volumetric efficiency. Volumetric efficiency (VE) of a compression cylinder may be influenced by a valve conversion. Clearance volume affects VE. Clearance volume is the volume in a cylinder end that is not swept by the movement of the piston. Depending on the size of the cylinder, clearance volume can range from 2% to as high as 60% of displacement, or more. It includes spaces between piston and head at the end of the stroke, space under the valves, and of course clearance within the piston side of the valve itself.
The higher the clearance the poorer the volumetric efficiency of the cylinder.
A compressor valve opens and closes with every compression cycle. The timing and pattern of these events are referred to as valve dynamics. It is important that the valve opens and closes at the right time and does not flutter. Compressor valve dynamics influence valve life and compression efficiency. Springing and the mass of the moving components affect valve dynamics. For proper performance, valves are designed for specific operating windows.
Compression ratio is the ratio of absolute discharge pressure to absolute inlet pressure.
Yes. An engineering analysis will determined or at least anticipate valve efficiency. Conducting a valve analysis prior to settling on a product increases the likelihood that the valve will operate properly with expected efficiency and durability upon installation. Purchasing valves based solely on price or availability does not offer the same assurance.
It is difficult, if not impossible, to predict how long a valve will work. There are, however, certain criteria that will increase the probability of lasting valve performance:
lower r.p.m.
lower valve lift
Sealing elements (plates, rings) with simple shape tend to have a higher fatigue resistance than parts of more intricate shape. Good mechanical cushioning and damping elements tend to minimize impact forces and definitely increase life. Air cushioned valves are not a mechanically controlled damping system. They depend solely on maintaining correct production tolerances, both in manufacture and after repair. Most sealing elements are made from glass-fiber or carbon fiber filled composite materials, such as nylon and PEEK. Steel plates and ring are less common. These new materials have proved very effective in valve applications. Composites work better in difficult services enduring contaminants and liquids in the gas stream. Non-metallic sealing elements tend to leak more than steel plates when new. This condition typically corrects itself once the compressor is running for several hours and the valve has worn-in. Remember that a valve opens and closes once for each compression cycle.
No, a compressor valve is an integral part of a larger piece of equipment. Often problems show up in the valve that is caused by outside factors. Carryover of foreign material can cause valve failure. Pulsations in the system can sometimes cause valve flutter. Changes in operational use from original design conditions are often the cause of frequent breakage. Improper valve repair and maintenance also cause short life. The list of possibilities is long.